PDF下载 分享
[1]冯 东,余小敏,张益林,等.基于变步长凸组合LMS自适应滤波高原动态血氧检测系统设计[J].成都信息工程大学学报,2024,39(02):142-147.[doi:10.16836/j.cnki.jcuit.2024.02.003]
 FENG Dong,YU Xiaomin,ZHANG Yilin,et al.Design of Motion SpO2 Detecting System based on VSCLSM Algorithm[J].Journal of Chengdu University of Information Technology,2024,39(02):142-147.[doi:10.16836/j.cnki.jcuit.2024.02.003]
点击复制

基于变步长凸组合LMS自适应滤波高原动态血氧检测系统设计

参考文献/References:

[1] Tsai W H,Lin B Y,Yang C C,et al.Assessment of vascular health with photoplethysmographic waveforms from the fingertip[J].IEEE Journal Biomedical Health Information,2017,21(2):382-386.
[2] 叶如陵.环境危害因素对高原旅行者健康的影响[J].中华疾病控制杂志,1999,3(4):309-310.
[3] 韩文波,曹维国.光电式脉搏波监测系统[J].长春光学精密机械学院学报,1999,22(4):30-34.
[4] 吴全玉,贾恩祥,戴飞杰,等.便携式低功耗可穿戴心率血氧监测系统的设计[J].江苏理工学院学报,2020,26(4):53-61.
[5] Maeda Y,Sekine M,Tamura T.Relationship between measurement site and motion artifacts inwearable reflected photoplethysmography[J].Journal of Medical Systems,2011,35:969-976.
[6] Poh M Z,Swenson N C,Picard R W.Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography[J].IEEE Transactions on Information Technology in Biomedicine,2010,14:786-794.
[7] Sharma H.Heart rate extraction from PPG signals using variational mode decomposition[J].Biocybernetics and Biomedical Engineering,2019,39(1):75-86.
[8] Sun B,Wang C C, Chen X H,et al.PPG signal motion artifacts correction algorithm based on feature estimation[J].Optik- International Journal for Light and Electron Optics,2019,176:337-349.
[9] Ram M R,Madhav K V,Krishna E H,et al.A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter[J].IEEE Transactions on Instrumentation and Measurement,2012,61(5):1445-1457.
[10] Peng F L,Zhang Z B,Gou X M,et al.Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter[J].Biomedical Engineering Online,2014,12:103-111.
[11] Islam M T,Ahmed S T,Zabir I,et al.Cascade and parallel combination(CPC)of adaptive filters for estimating heart rate during intensive physical exercise from photoplethysmographic signal[J].Healthcare Technology Letters,2018,5(1):18-24.
[12] Sun X,Ping Y, LI Y,et al.Robust heart beat detection from photoplethysmographyinterlaced with motion artifacts based on empirical mode decomposition[C].IEEE-EMBS International Conference on Biomedical & Health Informatics.IEEE,2012:775-778.
[13] 陈孝英,杨济民.基于STM32血氧心率检测仪的研制[J].电脑知识与技术,2017,13(15):231-233.
[14] 张虹,金捷,孙卫新.数字式脉搏血氧饱和度检测系统的研制[J].生物医学工程与临床,2002,3(6):125-128.
[15] 张林.运动状态下血氧饱和度检测算法研究[D].重庆:重庆理工大学,2021.

备注/Memo

收稿日期:2023-04-29
基金项目:四川省科技计划重点研发资助项目(2023YFS0468)

更新日期/Last Update: 2024-04-30