XIAO Feirui,ZHANG Yaxuan,FANG Shuhong,et al.Determination of Nitrosamines Disinfection By-products in Drinking Water Treatment Plant in Chengdu City by Ultra-high Performance Liquid Chromatography Tandem Mass Spectrometry[J].Journal of Chengdu University of Information Technology,2024,39(03):361-368.[doi:10.16836/j.cnki.jcuit.2024.03.014]
超高效液相色谱串联质谱法测定成都市某饮用水厂中的亚硝胺类消毒副产物
- Title:
- Determination of Nitrosamines Disinfection By-products in Drinking Water Treatment Plant in Chengdu City by Ultra-high Performance Liquid Chromatography Tandem Mass Spectrometry
- 文章编号:
- 2096-1618(2024)03-0361-08
- 关键词:
- 亚硝胺类; 消毒副产物; 饮用水厂; 消毒工艺; 超高效液相色谱串联质谱
- Keywords:
- nitrosamines; disinfection by-product; drinking water treatment plant; disinfection process; UPLC-MS/MS
- 分类号:
- X832
- 文献标志码:
- A
- 摘要:
- 自来水中亚硝胺类消毒副产物与常见的卤代消毒副产物比较,存在更高的毒性和致癌风险,近年来引起更多重视。拟在现有相关研究基础上优化自来水中亚硝胺类消毒副产物的超高效液相色谱串联质谱(UPLC-MS/MS)的检测方法,并对成都市某次氯酸钠消毒工艺的自来水厂中饮用水处理工艺过程中的亚硝胺浓度进行调查。选用活性炭固相萃取柱对水样中ng/L级别的亚硝胺类副产物进行富集净化,色谱柱采用ACQUITY Premier HSS T3柱(1.8 μm,2.1 mm×50 mm),乙腈和10 mmol/L乙酸铵/乙酸缓冲溶液(pH=4.1)作为流动相进行梯度洗脱,电喷雾离子源正离子模式,采集时选择多反应监测模式,以二甲基亚硝胺-d6为回收率指示物,亚硝基二丙胺-d14为定量内标,建立UPLC-MS/MS同时检测自来水中主要的9种亚硝胺类消毒副产物的分析方法。针对9种亚硝胺的方法检出限为1.04~2.19 ng/L,回收率74.71%~91.58%,标准曲线(省略样品前处理步骤)的线性范围为5~200 μg/L,线性相关系数r>0.99。二甲基亚硝胺的检出限低于《生活饮用水卫生标准》(GB 5749-2022)中规定的限值。前处理方法操作简单,能同时测定9种亚硝胺类消毒副产物。2022年4月对成都市某自来水厂进行实际调查,9种亚硝胺类消毒副产物均未检出,说明水源水中氨氮浓度较低的情况下,次氯酸钠消毒工艺对亚硝胺的形成影响不明显。
- Abstract:
- Compared with common halogenated disinfection byproducts, N-nitrosamines in drinking water have higher toxicity and carcinogenic risk, which has attracted more attention in recent years. The detection method of nitrosamines disinfection by-products in waterworks was optimized by ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS), and the method was applied to a drinking water plant in Chengdu under a sodium hypochlorite disinfection process. Active carbon column was used for solid-phase extraction at trace level(ng/L)in water samples. ACQUITY Premier HSS T3 column was used for separation, acetonitrile-10 mmol/L ammonium acetate and acetic acid buffer solution(pH=4.1)as mobile phase for gradient elution. An analytical method for simultaneous detection of 9 nitrosamines disinfection by-products in drinking water by UPLC-MS/MS was established, using NDMA-d6 as recovery indicator and NDPA-d14 as internal quantitative standard by ESI+ multiple reaction detection modes. The method detection limits of this analytical method for the nine nitrosamines rangefrom 1.04-2.19 ng/L. The recoveries were 74.71%-91.58%. The liner range(without sample pretreatment)was 5-200 μg/L, with r>0.99. The detection limit of dimethylnitrosamine is lower than that specified in the Standards for Drinking Water Quality(GB 5749-2022). The sample pretreatment method is simple. This method can determine 9 nitrosamines disinfection byproducts simultaneously. In April 2022, an investigation of a drinking water plant in Chengdu was carried out. It was found that none of the 9 main nitrosamines were detected. The effect of sodium hypochlorite disinfection process on the formation of nitrosamine was not obvious when concentrations of ammonia nitrogen were relatively low.
参考文献/References:
[1] Boyd JM,Hrudey SE,Li XF,et al.Solid-phase extraction and high-performance liquid chromatography mass spectrometry analysis of nitrosamines in treated drinking water and wastewater[J].Trends in Analytical Chemistry,2011,30(9):1410-1421.
[2] Zhao YY,Boyd J,Hrudey SE,et al.Characterization of new nitrosamines in drinking water using liquid chromatography tandem mass spectrometry[J].Environmental science & technology.2006,15; 40(24):7636-41.
[3] Topuz E,Aydin E,Pehlivanoglu-Mantas E,et al.A practical LC-MS/MS method for the detection of NDMA at nanogram per Liter concentrations in multiple water matrices[J].Water,Air and Soil Pollution2012,223:5793-5802.
[4] 汤庆会,余沛芝,陆坤,等.固相萃取-气相色谱串联质谱测定饮用水中N-亚硝胺类消毒副产物[J].净水技术,2018,37(10):28-32.
[5] 范文哲,姜遥,黄正根,等.固相萃取联合液相色谱-三重四级杆质谱测定饮用水中的亚硝胺类物质[J].西北师范大学学报(自然科学版),2019,55(1):73-78.
[6] 赵宇,杨潘青,孟君丽,等.超高效液相色谱/串联质谱同步测定水中多种亚硝胺类物质[J].净水技术,2019,38(4):21-27.
[7] 罗茜,王东红,王炳一,等.超高效液相色谱串联质谱快速测定饮用水中9种N-亚硝胺的新方法[J].中国科学:化学,2011,41(1):82-90.
[8] 唐雪惠,吴艳芬,李朝晖,等.超高效液相色谱质谱法测定饮用水中亚硝胺[J].化学研究与应用,2018,30(7):1190-1196.
[9] 朱翔,李伟,刘玉灿,等.超高效液相色谱-三重四极杆质谱联用仪同时检测水中9种亚硝胺[J].分析测试学报,2014,33(8):866-872.
[10] 姜遥.南方某城市饮用水中亚硝胺类消毒副产物的分布、形成和控制研究[D].上海:东华理工大学,2018.
[11] 张蓓蓓,赵永刚,孙慧婧,等.固相萃取-超高效液相色谱/三重四极杆质谱法同时测定地表水中8种亚硝胺类化合物[J].环境监控与预警,2020,12(5):82-86.
[12] 范文哲,姜遥,黄正根,等.固相萃取联合液相色谱-三重四级杆质谱测定饮用水中的亚硝胺类物质[J].西北师范大学学报(自然科学版),2019,55(1):73-78.
[13] 杨磊.水中亚硝胺类消毒副产物生成规律及其前质去除方法研究[D].哈尔滨:哈尔滨工业大学,2010.
[14] 殷世忠.N-亚硝基二甲胺在水处理过程中生成规律及影响因素研究[D].哈尔滨:哈尔滨工业大学,2007.
[15] 王佳仪.饮用水中亚硝胺的典型前体物的氯化特性及其控制[D].广州:暨南大学,2018.
[16] 周超.饮用水典型含氮消毒副产物亚硝胺类的生成机制研究综述[J].净水技术,2014,33(3):22-29.
[17] 罗曼,李凌,张付刚,等.2019年长江江苏段饮用水中二甲基亚硝胺的现状调查[J].环境与健康杂志,2019,36(11):1025-1028.
[18] 董蕾,王海燕,蔡宏铨,等.我国六城市饮用水中含氮消毒副产物的现状调查[J].环境与健康杂志,2016,33(3):232-235.
[19] 苏广宁,钟秀华,邓靖,等.固相萃取GC-MS测定饮用水中8种亚硝胺化合物[J].环境卫生学杂志,2022,12(1):64-69.
[20] 沈朝烨,蔡宏铨,裴赛峰,等.水中9种亚硝胺类化合物的固相萃取-气相色谱质谱联用测定方法[J].环境与职业医学,2019,36(11):1060-1065.
[21] 张力群,刘少颖,任韧,等.超高效液相色谱-串联质谱法检测生活饮用水8种N-亚硝胺类化合物[J].预防医学,2021,33(8):855-858.
备注/Memo
收稿日期:2022-11-02
基金项目:四川省科技计划项目-应用基础研究资助项目(2021YJ0384)
通信作者:孙静.E-mail:sunjing@cuit.edu.cn